TOSHIBA Top PageTOSHIBA ELECTRON TUBES & DEVICES CO.,LTD. Contact us
Toshiba Electron Tubes and Devices Co.,Ltd.
HOME  Company Overview | Site Map
X-Ray Tubes
Dental/Medical
Analytical/Industrial X-Ray Tubes
General
Angiography
Mammography
LM-CT X-Ray Tubes
X-Ray Image Intensifier
X-Ray Image Intensifier
Medical X-ray Imaging System
Industrial X-ray Imaging System
Microwave Tubes
High-Power Klystrons
Gyrotrons
Proportional Counters
Proportional Counters
Ionization Chambers
Neutron Proportional Counters (NPC)
Position Sensitive Detectors (PSD)
Sales Network   Production Facilities   Quality   Environment  
 
Transmitting Tubes
TRIODES
  • Air Cooling, Water Cooling
  • Triodes Tetrodes
  • Applications: Induction Heating for Industry
Tetrodes
 
Line Up

Technical data Down Load
Another window opens

Triodes <Plate Loss: Less than 1000W>

Type Heater or Filament Trans
Conduct.
(ms)
Amp.
Factor
μ
Max
Freq.
(MHz)
Max. Plate Ratings Output
Power
(kW)
Cooling
Volt
(V)
Curr.
(A)
Volt.
(kV)
Curr.
(mA)
Diss.
(W)
6T58RA 5 22 4.5 17 110 6 650 800 2.4 FA
E3061C** 6.3 32 6.5 45 50 7.5 750 800 2.5 FA
7815 ** 6 0.98 25 100 3,000 2 10 10 - C
Notes
1.Type** : For Maintenance use only
2.FA : Forced Air Cooling C : Conduction Cooling
UP

Triodes <Plate Loss : 1kW - less than 10kW>

Type Heater or Filament Trans
Conduct.
(ms)
Amp.
Factor
μ
Max
Freq.
(MHz)
Max. Plate Ratings Output
Power
(kW)
Cooling
Volt
(V)
Curr.
(A)
Volt.
(kV)
Curr.
(A)
Diss.
(kW)
7T69RB
12.6 35 13 21 110 8 2 4.5 9 FA
7T82JA 5 22 4.5 17 110 6 0.65 1.5 2.4 W
7T84B 6.3 22 4.5 17 110 7 0.8 2 3.8 W
7T84RB 6.3 22 4.5 17 110 7 0.8 1.5 3.8 FA
7T85RB 6.3 35 5 21 110 8 1 2.5 5.1 FA
E3062E 6.3 32 6.3 25 70 7.5 0.75 1.5 3.4 FA
8T20B 12 40 11 21 45 12 2.5 10 18 W
8T20RB 12 40 11 21 45 12 2.5 10 16 FA
8T30A 12 40 6.6 50 30 12 2 6 11 W
8T30RA 12 40 6.6 50 30 12 2 6 11 FA
8T64B 12 40 8 20 45 12 2 10 13 W
8T64RB 12 40 8 20 45 12 2 6 13 FA
8T69JB 12.6 35 12 21 110 8 2 6 9 W
8T85RB 12 40 11 21 40 12 2.5 10 17.5 FA
E3069 12.6 35 13 21 110 8 2.2 5 11 FA
E3097 ** 6.3 22 6.5 35 - 20 0.8 1.5 - FA
E3130 12.6 45 17 21 110 8 2.5 6 13 FA
E3170 12.6 35 10 21 110 8 2.2 5 11 FA
Notes
1.Type** : For Maintenance use only
2.FA : Forced Air Cooling W : Water Cooling
UP

Triodes <Plate Loss : 10kW - less than 100kW>

Type Heater or Filament Trans
Conduct.
(ms)
Amp.
Factor
μ
Max
Freq.
(MHz)
Max. Plate Ratings Output
Power
(kW)
Cooling
Volt
(V)
Curr.
(A)
Volt.
(kV)
Curr.
(A)
Diss.
(kW)
8T25RA
7.5-
8.5
110 24 20 40 14 4.5 15 31 FA
8T25 20 31 W
8T61A 8 280 30 20 40 14 8.5 35 57 W
8T72B 8 180 16 20 40 14 6.5 25 40 W
8T84A 8 180 16 20 40 14 6.5 30 42 W
8T85B 12 40 11 21 45 12 3 13 22 W
8T86B 12 40 11 21 45 12 3 13 22 W
8T87B 8 180 16 20 40 14 5 30 42 W
8T87RB 8 180 16 20 40 14 5 20 35 FA
9T16B ** 8 280 30 20 40 12 8.5 50 57 V
9T64B 12 320 70 30 25 15 15 75 137 W
9T71C 11 285 38 30 25 17 13 75 130 W
9T94A 13 320 70 30 25 16 16 80 170 W
E3080A 13 320 60 30 25 16 16 80 170 W
E3116 8 280 30 20 40 14 8.5 25 57 FA
Notes
1.Type** : For Maintenance use only
2.FA : Forced Air Cooling W : Water Cooling V : Vapor Cooling
UP

Triodes <Plate Loss: Over 100kW>

Type Heater or Filament Trans
Conduct.
(ms)
Amp.
Factor
μ
Max
Freq.
(MHz)
Max. Plate Ratings Output
Power
(kW)
Cooling
Volt
(V)
Curr.
(A)
Volt.
(kV)
Curr.
(A)
Diss.
(kW)
9T38A/
LD961
18.3 315 90 40 2 15 20 120 210 W
9T40 ** 18 315 80 40 2 15 20 150 240 V
9T83 ** 18 315 80 40 2 15 20 150 240 V
E3050/
9T75
17.5 470 130 30 2 15 40 250 450 W
E3085 15.8-
18
450 130 30 2 15 40 250 320 W
E3109 ** 18 315 80 40 2 15 20 150 240 V
Notes
1. Type** : For Maintenance use only
2.W : Water Cooling V : Vapor Cooling
UP

Tetrodes <Plate Diss Up To 1000W >

Type Heater or Filament Trans
Conduct.
(ms)
Use
Max
Freq.
(MHz)
Max. Ratings Plate
Output
(W)
Cooling
Volt
(V)
Curr.
(A)
Plate Volt.
(V)
Plate Curr.
(mA)
Plate Diss.
(W)
7F37R 4.0 35 15(0.4) CT *
ABI**
SSB
130
30
4000
5000
700
700
1000
1000
1250
1800
FA
Notes
1.* In case for operating 90MHz.  ** In case for operating below 30MHz.
2.FA : Forced Air Cooling
UP

Tetrodes <Plate Diss Up To 10kW >

Type Heater or Filament Trans
Conduct.
(ms)
Use
Max
Freq.
(MHz)
Max. Ratings Plate
Output
(W)
Cooling
Volt
(V)
Curr.
(A)
Plate Volt.
(V)
Plate Curr.
(A)
Plate Diss.
(W)
7F71R 4.0 78 65 (1.6) CT *
BTV**
130
300
5000
5000
1.8
1.8
3500
3500
5000
1100
FA
8F45R 7.5 75 23 (1.0) CT
CP
ABI
110
110
110
8000
5500
8000
3.0
2.5
3.0
5000
5000
5000
14000
5500
6000
FA
E3030B 7.5 24 8.3 (0.2) Switch & regulator - 100000

***5

1500 - OFA
E3113 7.5 17 8.2 (0.2) Switch - 150000 ***3 1300 - O
Notes
1.* In case for operating 90MHz.  ** In case for operating below 30MHz.
 *** Pulse plate current.  
2.FA : Forced Air Cooling OFA : Oil or Forced air cooling O : Oil cooling
UP

Tetrodes <Plate Diss 10kW Up>

Type Heater or Filament Trans
Conduct.
(ms)
Use
Max
Freq.
(MHz)
Max. Ratings Plate
Output
(kW)
Cooling
Volt
(V)
Curr.
(A)
Plate Volt.
(V)
Plate Curr.
(A)
Plate Diss.
(kW)
8F67R 6.9-7.5 126 65 (3.0) CT
BTV**
230
230
8000
8000
4.5
6
15
15
15.5***
15.2***
FA
8F68 8.5 185 85 (3.0) CT
BTV*
220
220
11000
11000
9
12
30
30
40
30
VF
8F68R 8.5 185 85 (3.0) CT
BTV*
220
220
10000
10000
8
10
25
25
40
30
FA
8F76R 7.5 120 60 (2.5) CT
BTV*
250
250
10000
10000
4.5
5.5
15
15
15
12
FA
9F45 16 345 150 (10) CT**
CP**
30
30
15000
15000
25
20
150
100
250
150
VF
Notes
1.* Bandwidth of 6.0MHz,sync.Level.
 * In grounded control-grid Screen-grid curcuit. ** In case for operating below 30MHz.
 ***
Effective power.
2.FA : Forced Air Cooling VF : Vapor cooling, Forced ventilation
UP
HOME
previous next
TOSHIBA top page | PrivacyPolicy Copyright